Flow Transmitter / Switch OMNI-RT
Flow Transmitter / Switch OMNI-RT
● Universal turbine flow sensor
● Analog output, two switching outputs
● Clear, easily legible, illuminated LCD display
● Modifiable units in the display
● Designed for industrial use
● Small, compact construction
● Simple installation
Characteristics :
A turbine acts as the primary sensor; its rotational speed is proportional to the flow rate. The rotational speed is detected by means of pre-tensioned Hall sensors, i.e. there are no magnets in the flow space. The OMNI transducer located on the sensor has a backlit graphics LCD display which is very easy to read, both in the dark and in bright sunlight.
A turbine acts as the primary sensor; its rotational speed is proportional to the flow rate. The rotational speed is detected by means of pre-tensioned Hall sensors, i.e. there are no magnets in the flow space. The OMNI transducer located on the sensor has a backlit graphics LCD display which is very easy to read, both in the dark and in bright sunlight.
The graphics display allows the presentation of measured values and parameters in a clearly understandable form. The measured values are displayed to 4 places, together with their physical unit, which may also be modified by the user.
The electronics have an analog output (4..20 mA or 0..10 V) and two switching outputs, which can be used as limit switches for monitoring minimal or maximal, or as two-point controllers. The switching outputs are designed as push-pull drivers, and can therefore be used both as PNP and NPN outputs.
Exceeding limit values is signalled by a red LED which is visible over a long distance, and by a cleartext in the display. The stainless steel case has a hardened non-scratch mineral glass pane. It is operated by a programming ring fitted with a magnet, so there is no need to open the operating controls housing, and its leakproofness is permanently ensured.
By turning the ring to right or left, it is simple to modify the parameters (e.g. switching point, hysteresis...). To protect from unintended programming, it can be removed, turned through 180 ° and replaced, or completely removed, thus acting as a key
Fiche technique
- Medium temperature
- -20..+85 °C optionally -20..+150 °C (for 8 bar min.)
- Ambient temperature
- -20..+70 °C
- Sensor
- Flow Transmitter RT-...AK
- Nominal width
- DN 15..50
- Process connection
- G 1 /2 A...G 2 A
- Metering ranges
- see table "Ranges"
- Measurement accuracy
- ±1 % of full scale value in the specified metering range including linearity and repeatability
- Storage temperature
- -20..+80 °C
- Pressure loss (average)
- maximum 0.3 bar at Qmax
- Display