Switching Head
keyboard_arrow_rightkeyboard_arrow_left

Switching Head

Review (0)

Switching Head A-V3   For devices VM-

● II 2G Ex d IIC T6 Gb


Switching head with pressure-resistant encapsulation and ATEX approval for the VM range of devices.

Switch              : micro switch

Handling and operation
Note


● Cable lengths max. 5 m.
● It must be ensured that the values given for voltage, current,
and power are not exceeded.
● When switched on, a load must be connected in series.
● The electrical details apply to ohmic loads.
Capacitive, inductive and lamp loads must be operated using a
protective circuit.


Adjustment


To adjust the switching point, the fixing screw for the switching
head must be loosened. The switching head can then be rotated.
Turning to the right increases the switching point, and vice-versa.
Then retighten the fixing screw.

Donnez votre avis
EU3234363840424446USXX5XSSMLXLXXLXXLArm Length6161,56262,56363,56464,5Bust Circumference8084889296101106111Waist Girth6165697377828792Hip Circumference87919599103108113118
  • Garanties sécuritéGaranties sécurité
  • Politique de livraisonPolitique de livraison
  • Politique retoursPolitique retours

Switching Head A-V3   For devices VM-

● II 2G Ex d IIC T6 Gb


Switching head with pressure-resistant encapsulation and ATEX approval for the VM range of devices.

Switching voltage                  : max. 250 V AC
Switching current                  : max. 5 A
Protection class                      2 - safety insulation
Ingress protection                :  IP 65
Electrical                               : cable 2.5 m, other cable lengths optionally
connection                            : available

Switch              : micro switch

Handling and operation
Note


● Cable lengths max. 5 m.
● It must be ensured that the values given for voltage, current,
and power are not exceeded.
● When switched on, a load must be connected in series.
● The electrical details apply to ohmic loads.
Capacitive, inductive and lamp loads must be operated using a
protective circuit.


Adjustment


To adjust the switching point, the fixing screw for the switching
head must be loosened. The switching head can then be rotated.
Turning to the right increases the switching point, and vice-versa.
Then retighten the fixing screw.


Ordering code


The base device is ordered, e.g. VM-015GR020A with switching
head e.g. A-V3-1.

Use for devices


Switching head           Device type

A-V3                              VM-...

GHM Messtechnik Maroc
A-V3

Fiche technique

Température
-20..+50 °C Ambient
-20..+90 °C