• Nouveau

Flow Display H1O1 / H2O1

H101/H201

Flow Display H1O1 / H2O1

● No electrical supply required
● Individually calibrated display
● Compact design

Characteristics :
A piston fitted with a magnet is pushed through the medium against
the force of a spring. This activates the pointer of the measuring
device by means of a magnetic coupling. Because of the hermetic
separation from the medium, the display unit cannot be soiled by
the medium.

Ranges :
Details in the table correspond to horizontal inwards flow with
increasing flow rate.

Handling and Operation :
● Include straight calming section of 5 x DN in inlet and outlet.
● If the media are dirty, install a filter
(use magnetic filter for ferritic components)

Flow Display H1O1 / H2O1

● No electrical supply required
● Individually calibrated display
● Compact design

Characteristics :
A piston fitted with a magnet is pushed through the medium against
the force of a spring. This activates the pointer of the measuring
device by means of a magnetic coupling. Because of the hermetic
separation from the medium, the display unit cannot be soiled by
the medium.

Ranges :
Details in the table correspond to horizontal inwards flow with
increasing flow rate.

Handling and Operation :
● Include straight calming section of 5 x DN in inlet and outlet.
● If the media are dirty, install a filter
(use magnetic filter for ferritic components)

H101/H201

Fiche technique

Connexion
female thread G 1/4..G 1 (further process connections available on request
Switch
without
Ambient temperature
-20..+70 °C
Nominal width
DN 8..25
Pressure loss (average)
0.4..3.5 bar at Qmax
Display
0.1..85 l/min range
Weight
see table "Dimensions and weights"
Qmax
to 100 l/min
Tolerance
±5 % of full scale value
Pressure resistance
PN 200 bar optionally PN 500 bar
Media
water, oils (gases and aggressive media available on request)
Materials medium-contact
Brass construction: CW614N nickelled, CW614N, 1.4310, hard ferrite, NBR - Stainless steel construction: 1.4571, 1.4404, 1.4310, hard ferrite PTFE-coated, FKM
Non-mediumcontact materials
PC, acrylic
Installation location
Standard: horizontal inwards flow from the left; other installation positions are possible; the installation position affects the display range.
Media temperature
-20..+120 °C