Subcategories

Filtres actifs

  • Flow Transmitter / Switch OMNI-RT

    Flow Transmitter / Switch OMNI-RT 

    ● Universal turbine flow sensor

    ● Analog output, two switching outputs

    ● Clear, easily legible, illuminated LCD display

    ● Modifiable units in the display

    ● Designed for industrial use

    ● Small, compact construction

    ● Simple installation

    Characteristics :

    A turbine acts as the primary sensor; its rotational speed is proportional to the flow rate. The rotational speed is detected by means of pre-tensioned Hall sensors, i.e. there are no magnets in the flow space. The OMNI transducer located on the sensor has a backlit graphics LCD display which is very easy to read, both in the dark and in bright sunlight. 

  • Flow Transmitter RT-...AK

    Flow Transmitter RT-...AK

    ● High precision

    ● No magnetic components in the flow space

    ● High pressure resistance 

     Characteristics :

    A turbine acts as the primary sensor; its rotational speed is proportional to the flow rate.

    The rotational speed is detected by means of a biased Hall sensors, i.e. there are no magnets in the flow space.

  • Flow Transmitter LABO-RT-I / U / F / C

    Flow Transmitter LABO-RT-I / U / F / C 

    ● High precision

    ● No magnetic components in the flow space

    ● High pressure resistance

    ● 0..10 V, 4..20 mA , frequency/pulse output, completely configurable

    Characteristics :

    A turbine acts as the primary sensor; its rotational speed is proportional to the flow rate. The rotational speed is detected by means of pre-tensioned Hall sensors, i.e. there are no magnets in the flow space. The LABO-RT electronics make various output signals available:

    ● Analog signal 0/4..20 mA (LABO-RT-I)

    ● Analog signal 0/2..10 V (LABO-RT-U)

    ● Frequency signal (LABO-RT-F) or

    ● Value signal pulse / x litres (LABO-RT-C)

    A model with switching output is also available (see separate datasheet).

    If desired, the range end value can be set to the currently existing flow using "teaching"

  • Switching head A-H1.1

    Switching head A-H1.1

    ● I M1 Ex ia I Ma
    ● II 1G Ex ia IIC T4 Ga
    ● II 1D Ex ia IIIC T135°C Da

    Characteristics  :

    Intrinsically safe switching head with reed switch and ATEX
    approval, for the HD range of devices, for use in intrinsically safe power circuits.

    Handling and operation
    Note
    All
    ●For use only in intrinsically safe power circuits - provide a suitable isolating amplifier.
    ●Cable lengths max. 5 m.
    ●It must be ensured that the values given for voltage, current, and power are not exceeded.
    ●When switched on, a load must be connected in series.
    ●The electrical details apply to ohmic loads. Capacitive, inductive and lamp loads must be operated using a protective circuit.


    HD1KO- / HD2KO-
    ●Display with plastic parts - do not open in an explosive atmosphere.

  • Flow Transmitter / Switch FLEX-RT

    Flow Transmitter /Switch FLEX-RT

    ● Versatile turbine flow sensor
    ● Switching output and analog output (4..20 mA / 0..10 V)
    ● Top quality materials
    ● Designed for industrial use
    ● Ingress protection IP 67
    ● Infinitely adjustably rotatable cable outlet for clean
    alignment
    ● Small, compact construction
    ● Very simple installation

    Characteristics :

    A turbine acts as the primary sensor; its rotational speed is
    proportional to the flow rate. The rotational speed is detected by
    means of a biased Hall sensors, i.e. there are no magnets in the
    flow space.
    The FLEX transducer located on the sensor has an analog output
    (4..20 mA or 0..10 V) and a switching output, which can be
    configured as a limit switch for monitoring minimal or maximal, or
    as a frequency output.



  • Flow Switch LABO-RT-S

    Flow Switch LABO-RT-S

    ● Very short response time
    ● High precision
    ● No magnetic components in the flow space
    ● High pressure resistance

    Characteristics

    A turbine acts as the primary sensor; its rotational speed is
    proportional to the flow rate. The rotational speed is detected by
    means of pre-tensioned Hall sensors, i.e. there are no magnets in
    the flow space.
    The integrated converter / counter make available an electronic
    switching output (push-pull) with adjustable characteristics
    (minimum/maximum) and hysteresis, which responds when an
    adjustable limit is fallen short of or exceeded.
    The switching value can be set to the currently existing flow using
    "teaching".
    Models with analog or pulse output are also available.

  • Flow Indicator HV

    Flow Indicator HV

    ● Bidirectional
    ● 360 ° visibility

    Characteristics :

    The flow indicator HV is used for the reliable display of transparent
    fluids. A signal-red turbine wheel rotates in a glass tube
    proportional to the flow, and in this way provides an indication of
    the flow rate present.
    The devices provide 360 ° vision, and are built for a long working
    life, thanks to the design of the turbine's bearings.

  • Flow Switch MR1K-

    Flow Switch MR1K

    ● High switching power
    ● Compact design

    Characteristics :

    Mechanical flow switch, for fluid or gaseous media, with
    spring-supported piston and magnetic triggering of a reed switch.
    Robust construction in brass or stainless steel.

    Handling and Operation
    Note
    ● Include straight calming section of 5 x DN in inlet and outlet
    ● Include a filter if the media are dirty (use magnetic filter for
    ferritic components).
    ● It must be ensured that the values given for voltage, current,
    and power are not exceeded.
    ● When switch on, a load must be connected in series.
    ● The electrical details apply to ohmic loads. Capacitive,
    inductive and lamp loads must be operated using a protective circuit.


    Adjustment
    If it is necessary to set the switching value,
    the switching head can be adjusted
    lengthways.

  • Flow Switch FX

    Mechanical flow switch, for fluid media, with magnetic triggering of a reed switch. Plastic housing with integrated filter.

    ● Adjusted switching value
    ● Integrated filter
    ● High switching power
    ● Optional flow limiter in the outlet piece

    Handling and operation


    ● Include straight calming section of 5 x DN in inlet and outlet
    ● It must be ensured that the values given for voltage, current,
    and power are not exceeded.
    ● When switch on, a load must be connected in series.
    ● The electrical details apply to ohmic loads. Capacitive,
    inductive and lamp loads must be operated using a protective circuit.

  • Switching Head

    • I M1 Ex ia I Ma
    • II 1G Ex ia IIC T4 Ga
    • II 1D Ex ia IIIC T135°C Da

    Intrinsically safe switching head with reed switch and ATEX approval, for the VD range of devices, for use in intrinsically safe power circuits.

  • Transmetteur numérique 2...
    • Nouveau
    • En rupture de stock

    Transmetteur numérique 2 voies ( MAROC )

    Un transmetteur pour + de 40 sondes et 14

    paramètres

    Le transmetteur numérique SC 200 à 2 voies est

    compatible avec notre gamme complète de sondes

    numériques et analogiques. Plus de 40 sondes sont

    disponibles, parmi lesquelles des sondes de mesure

    d‘ammonium et de turbidité ainsi que des sondes de

    mesure de paramètres spéciaux comme l‘huile dans

    l‘eau. Le transmetteur tout-en-un et sa gamme de

    sondes surveillent les procédés pour toutes les

    applications dans les eaux usées, potables et

    industrielles. La standardisation en un seul transmetteur

    réduit la complexité inhérente à la maintenance, les

    temps d‘interruption et les coûts. Vous n‘avez en outre

    qu‘un seul interlocuteur pour tous ces paramètres.