Nouveaux produits
Nouveaux produits
Our Client Says
Our Client Says
Métrologie industrielle
Subcategories
-
Flow Indicator FH-...GR
Flow Indicator FH-...GR
● No moving parts internally
● Installation location as desired
● For heavily soiled or coloured fluids
● Double-sided large-surface window
● Natural glass
Characteristics :
Devices made from solid red bronze, where the medium can be visually examined through the sight glass (fluid level, colour, bubbles,...)
-
Flow Indicator OW-...GM
Technical Data WO1-...GM/K
● No moving parts internally
● Installation location as desired
● For heavily soiled or coloured fluids
● Natural glass, acrylic glass
Characteristics :
Devices made from solid brass, where the medium can be visually examined through the sight glass (fluid level, colour, bubbles,...)
-
Flow indicator, sight glass WO1-…GM/K
Flow indicator, sight glass WO1-…GM/K
● No moving parts internally
● Internal wiper provides ability to clean the glass without removing the device.
● Installation location as desired
● For heavily soiled or coloured fluids
● 360 ° visibility
Characteristics :
Devices made from solid brass or stainless steel, where the medium can be visually examined through the sight glass (fluid level, colour, bubbles, ...). A wiper makes it possible to clean the sight glass.
-
Flow Indicator SK-...GR
Flow Indicator SK-...GR
● High temperature resistance
● Double-sided large-surface window
● Natural glass
● Display of flow rate
Characteristics :
Mechanical flow indicator for fluid media. A stainless steel flap in the area of flow is lifted by the volume flow, and indicates the present flow rate.
-
Flow Display H1O1 / H2O1
Flow Display H1O1 / H2O1
● No electrical supply required
● Individually calibrated display
● Compact designCharacteristics :
A piston fitted with a magnet is pushed through the medium against
the force of a spring. This activates the pointer of the measuring
device by means of a magnetic coupling. Because of the hermetic
separation from the medium, the display unit cannot be soiled by
the medium.Ranges :
Details in the table correspond to horizontal inwards flow with
increasing flow rate.Handling and Operation :
● Include straight calming section of 5 x DN in inlet and outlet.
● If the media are dirty, install a filter
(use magnetic filter for ferritic components) -
Signal converter LABO-W...I / U / F / C
Signal converter LABO-W...I / U / F / C
● Signal converter for looping into the sensor line
● Conversion of voltages, currents or frequencies into current, voltage, frequency or pulse signals
● 16-bit microcontroller
● Linearized
● Numerous configurable parameters
● A parameter can be set locally
● AffordableCharacteristics :
The LABO-W signal converters are designed for the measurement
of sensor signals and their conversion into standard signals (cur-
rent 4..20 mA, voltage 0..10 V, frequencies up to 2 kHz, pulse sig-
nals). For this purpose, they have a powerful 16-bit microcontroller
in their compact housing. -
Limit switch LABO-W...S
Limit switch LABO-W...S
● Limit switch for looping into the sensor line
● Evaluation of voltages, currents or frequencies
● 16-bit microcontroller
● Numerous configurable parameters
● A parameter can be set locally
● Affordable
Characteristics :
The LABO-W limit switches are designed for the measurement and evaluation of sensor signals. For this purpose, they have a powerful 16-bit microcontroller in their compact housing. The standard versions are designed such that currents, voltages and frequencies which are common for industrial applications can be measured.
-
Flow Transmitter / Switch FLEX-RT
Flow Transmitter /Switch FLEX-RT
● Versatile turbine flow sensor
● Switching output and analog output (4..20 mA / 0..10 V)
● Top quality materials
● Designed for industrial use
● Ingress protection IP 67
● Infinitely adjustably rotatable cable outlet for clean
alignment
● Small, compact construction
● Very simple installationCharacteristics :
A turbine acts as the primary sensor; its rotational speed is
proportional to the flow rate. The rotational speed is detected by
means of a biased Hall sensors, i.e. there are no magnets in the
flow space.
The FLEX transducer located on the sensor has an analog output
(4..20 mA or 0..10 V) and a switching output, which can be
configured as a limit switch for monitoring minimal or maximal, or
as a frequency output. -
Flow Switch MR1K-
Flow Switch MR1K
● High switching power
● Compact designCharacteristics :
Mechanical flow switch, for fluid or gaseous media, with
spring-supported piston and magnetic triggering of a reed switch.
Robust construction in brass or stainless steel.Handling and Operation
Note
● Include straight calming section of 5 x DN in inlet and outlet
● Include a filter if the media are dirty (use magnetic filter for
ferritic components).
● It must be ensured that the values given for voltage, current,
and power are not exceeded.
● When switch on, a load must be connected in series.
● The electrical details apply to ohmic loads. Capacitive,
inductive and lamp loads must be operated using a protective circuit.
Adjustment
If it is necessary to set the switching value,
the switching head can be adjusted
lengthways. -
convertisseur de mesure Humidité/température
convertisseur de mesure Humidité/température
(tube de sonde latéral, FL = 50 mm)
- Affichage sur site de la température et de l'humidité atmosphérique
- Signal sortie entièrement modulable
- Plage de température jusqu'à 120 °C
- Réétalonnage par l'utilisateur possible
- Séparation galv. des canaux Humidité atmosphérique et Température
- Signaux de sortie possibles : 4-20 mA, 0-1 V ou 0-10 V
-
Capteurs de pression en acier inoxydable
Capteur de pression en acier inoxydable (parties en contact) convient aux milieux agressifs, à l'eau, etc.
-
Capteurs de pression en acier inoxydable
Capteur de pression en acier inoxydable (parties en contact) convient aux milieux agressifs, à l'eau, etc
-
Convertisseurs de mesure de pression surpression, dépression et pression absolue
Convertisseurs de mesure de pression surpression, dépression et pression absolue : S-10 REL
(standard, zéro électrique pour pression atmosphérique)
Description : Capteur de pression piézorésistif avec comp. de temp. Modèle
inox. entièrement soudé avec matière de remplissage compatible usage
alimentaire (16 bar max.) ou DMS à couche mince (à partie de 25 bar).Plages de mesure : en bar (autres valeurs sur demande)
S-10 REL und S-11REL : 0,1, 0,16, 0,25, 0,4, 0,6, 1, 1,6, 2,5, 4, 6, 10, 16, 25, 40, 60, 100, 160, 250, 400, 600, 1000
S-10 ABS et S-11ABS : 0,25, 0,4, 0,6, 1, 1,6, 2,5, 4, 6, 10, 16
Plages de mesure (PM), Seuil de surcharge (SC)
-
Convertisseurs de mesure de pression
Convertisseurs de mesure de pression (pression rel., zéro électr. pour pression atm.) : A-10
Utilisation générale : Toutes applications pour l'industrie des machinesoutils
et équipements, la robotique et le génie climatique et frigorifique.Plage de mesure (PM), surcharge (SC), pression d'éclatement (PE) en bar :
- PM : 1, 1.6, 2.5, 4, 6, 10, 16, 25, 40, 60, 100, 160, 250, 400, 600
- SC : 2 3,2 5 8 12 20 32 50 80 120 200 320 500 800 1200
- PE : 5 10 10 17 34 34 100 100 400 550 800 1000 1200 1700 2400
Signal sortie : 4-20 mA, deux fils, RA [Ω] < (Uv [V] - 8 V)/0,02 A
0-10 V, trois fils, RA > 10 kΩ
Courant auxiliaire Uv : 8-30 Vc.c. (avec sortie : 4-20 mA)
-
Convertisseur de mesure de redox
GRMU 2000 MP sans électrode Convertisseur de mesure de redox à séparation galvanique .
Transducteur de mesure Redox sans électrode, connexion BNC -
Convertisseur de mesure du pH
convertisseur de mesure pH de qualité avec compensation automatique de la température (avec sonde thermométrique enfichée).
Particularités
- Compensation de température manuelle ou automatique
- Sonde de température Pt1000 externe raccordable
- Entrée capteur à séparation galvanique
- Étalonnage à 2 points
-
Convertisseur de mesure du pH
convertisseur de mesure pH de qualité avec compensation automatique de la température (avec sonde thermométrique enfichée).
Particularités :
• Compensation de température manuelle ou automatique
• Sonde de température Pt1000 externe raccordable
• Entrée capteur à séparation galvanique
• Étalonnage à 2 points
-
Convertisseur de mesure d'oxygène pour de l'oxygène dissous dans des liquides
Convertisseur de mesure d'oxygène pour de l'oxygène dissous dans des liquides
-
Convertisseurs de mesure de la conductivité
Transmetteur de mesure de conductivité avec électrode 4 pôles
Domaines d'application
• Concentrations élevées de sel (p. ex. mesure liquide antigel)
• Mesure dans solutions polluées / eaux usées
• Examen de neutralisations
• Liquides fortement pollués -
Convertisseurs de mesure de la conductivité
GLMU 200 MP : Convertisseurs de mesure de la conductivité avec cellule de mesure à 2 pôles
Domaines d'application
• Mesures de conductivité simples et avantageuses
• Surveillance de l'eau potable
• Pisciculture/surveillance des cours d'eau
• Aquariophilie d'eau douce et d'eau de mer